Vladislav Tverdochleb, Author at Schneider Electric Blog https://blog.se.com Global Specialist in Energy Management and Automation Thu, 06 Jan 2022 20:53:25 +0000 en-US hourly 1 Best Electrician – Tell a story to grow your business https://blog.se.com/power-management-metering-monitoring-power-quality/2015/01/20/best-electrician-tell-story-grow-tour-business/ https://blog.se.com/power-management-metering-monitoring-power-quality/2015/01/20/best-electrician-tell-story-grow-tour-business/#comments Tue, 20 Jan 2015 05:00:39 +0000 http://blog.schneider-electric.com/?p=17462 If you’re a top, confident electrician you’re creative. You’re a storyteller. You have a fund of tales from all walks of life and your own personal experience. Use them. How... Read more »

The post Best Electrician – Tell a story to grow your business appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2015/01/20/best-electrician-tell-story-grow-tour-business/feed/ 11
Best Electrician – The extra something is a solution not a device https://blog.se.com/power-management-metering-monitoring-power-quality/2015/01/13/best-electrician-extra-something-electricians-sell-customer-solution-device/ Tue, 13 Jan 2015 05:00:53 +0000 http://blog.schneider-electric.com/?p=17458 The big electrical equipment manufacturing companies today – like the one I work for – are increasingly producing integrated solutions. They are the “extra something” confident electricians propose when they... Read more »

The post Best Electrician – The extra something is a solution not a device appeared first on Schneider Electric Blog.

]]>
Best Electrician – Learning more, earning more https://blog.se.com/power-management-metering-monitoring-power-quality/2015/01/06/best-electrician-learning-earning/ https://blog.se.com/power-management-metering-monitoring-power-quality/2015/01/06/best-electrician-learning-earning/#comments Tue, 06 Jan 2015 05:00:22 +0000 http://blog.schneider-electric.com/?p=17454 As a good electrician’s reputation grows, so does his (her) business. So, too, do his (her) self-confidence and experience. Increasingly, he (or she) is able to work on his (her)... Read more »

The post Best Electrician – Learning more, earning more appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2015/01/06/best-electrician-learning-earning/feed/ 18
Best Electrician – Goes Beyond Customer Expectations https://blog.se.com/power-management-metering-monitoring-power-quality/2014/12/16/best-electrician-goes-beyond-customer-expectations/ https://blog.se.com/power-management-metering-monitoring-power-quality/2014/12/16/best-electrician-goes-beyond-customer-expectations/#comments Tue, 16 Dec 2014 05:00:36 +0000 http://blog.schneider-electric.com/?p=17450 All you electricians out there, what do you think makes a good electrician? Not an easy question to answer when you consider how many hundreds and thousands of you are... Read more »

The post Best Electrician – Goes Beyond Customer Expectations appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2014/12/16/best-electrician-goes-beyond-customer-expectations/feed/ 16
IEC 60898-1 and IEC 60947-2: a tale of two standards https://blog.se.com/energy-regulations/2014/02/06/iec-60898-1-iec-60947-2-tale-two-standards/ https://blog.se.com/energy-regulations/2014/02/06/iec-60898-1-iec-60947-2-tale-two-standards/#comments Thu, 06 Feb 2014 05:00:09 +0000 http://blog.schneider-electric.com/?p=11849 In response to the question “What’s the difference between standards IEC 60898-1 and IEC 60947-2?”,  I’m tending to answer with another question: What do they have in common?  They are... Read more »

The post IEC 60898-1 and IEC 60947-2: a tale of two standards appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/energy-regulations/2014/02/06/iec-60898-1-iec-60947-2-tale-two-standards/feed/ 58
Cascading and backup: Why coordination should be compulsory https://blog.se.com/power-management-metering-monitoring-power-quality/2013/12/17/cascading-backup-coordination-compulsory/ https://blog.se.com/power-management-metering-monitoring-power-quality/2013/12/17/cascading-backup-coordination-compulsory/#comments Tue, 17 Dec 2013 05:00:50 +0000 http://blog.schneider-electric.com/?p=11831 This blog was updated in March 2020 to better reflect changes in the market. In our first blog we touched on the coordination of combined short-circuit devices and backup devices.... Read more »

The post Cascading and backup: Why coordination should be compulsory appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2013/12/17/cascading-backup-coordination-compulsory/feed/ 1
Selectivity: Positive discrimination for maximum safety https://blog.se.com/power-management-metering-monitoring-power-quality/2013/12/10/selectivity-positive-discrimination-maximum-safety/ https://blog.se.com/power-management-metering-monitoring-power-quality/2013/12/10/selectivity-positive-discrimination-maximum-safety/#comments Tue, 10 Dec 2013 05:00:17 +0000 http://blog.schneider-electric.com/?p=11824 This blog was updated in March 2020 to better reflect changes in the market. “Selectivity”? “Discrimination”? Why do they mean the same thing? The terms denote “selective” or “discriminative” tripping.... Read more »

The post Selectivity: Positive discrimination for maximum safety appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2013/12/10/selectivity-positive-discrimination-maximum-safety/feed/ 3
Setting the standard for coordination https://blog.se.com/energy-regulations/2013/12/03/setting-standard-coordination/ Tue, 03 Dec 2013 05:00:44 +0000 http://blog.schneider-electric.com/?p=11820 This blog was updated in March 2020 to better reflect changes in the market. It’s about time a standard underlining the critical need for coordinating protective devices was published. European... Read more »

The post Setting the standard for coordination appeared first on Schneider Electric Blog.

]]>
IEC 60947-2 the “all-risk” insurance for circuit breakers – Part 3 https://blog.se.com/power-management-metering-monitoring-power-quality/2013/08/08/iec-60947-2-the-all-risk-insurance-for-circuit-breakers-part-3/ https://blog.se.com/power-management-metering-monitoring-power-quality/2013/08/08/iec-60947-2-the-all-risk-insurance-for-circuit-breakers-part-3/#comments Thu, 08 Aug 2013 04:00:43 +0000 http://blog.schneider-electric.com/?p=8725 This is the third part of my blog on selecting a circuit breaker. And there are still some more IEC 60947 2 requirements to consider. Reference voltages One I reckon... Read more »

The post IEC 60947-2 the “all-risk” insurance for circuit breakers – Part 3 appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2013/08/08/iec-60947-2-the-all-risk-insurance-for-circuit-breakers-part-3/feed/ 4
IEC 60947-2 the “all-risk” insurance for circuit breakers – Part 2 https://blog.se.com/power-management-metering-monitoring-power-quality/2013/07/26/iec-60947-2-the-all-risk-insurance-for-circuit-breakers-part-2/ https://blog.se.com/power-management-metering-monitoring-power-quality/2013/07/26/iec-60947-2-the-all-risk-insurance-for-circuit-breakers-part-2/#comments Fri, 26 Jul 2013 04:00:10 +0000 http://blog.schneider-electric.com/?p=8720 IEC 60947-2 obviates risk and ensures safety and reliability. Its requirements have grown in number to keep pace with evolving technologies and reliability needs of electrical distribution. Circuit breaker categories... Read more »

The post IEC 60947-2 the “all-risk” insurance for circuit breakers – Part 2 appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2013/07/26/iec-60947-2-the-all-risk-insurance-for-circuit-breakers-part-2/feed/ 13
IEC 60947-2 the “all-risk” insurance for circuit breakers – Part 1 https://blog.se.com/power-management-metering-monitoring-power-quality/2013/07/16/iec-60947-2-the-all-risk-insurance-for-circuit-breakers/ https://blog.se.com/power-management-metering-monitoring-power-quality/2013/07/16/iec-60947-2-the-all-risk-insurance-for-circuit-breakers/#comments Tue, 16 Jul 2013 04:00:30 +0000 http://blog.schneider-electric.com/?p=8712 IEC 60947-2 has been around a while. Originally called IEC 947-2, it got its current name way back in 1997. So, you may wonder, why talk about it now? Let’s... Read more »

The post IEC 60947-2 the “all-risk” insurance for circuit breakers – Part 1 appeared first on Schneider Electric Blog.

]]>
https://blog.se.com/power-management-metering-monitoring-power-quality/2013/07/16/iec-60947-2-the-all-risk-insurance-for-circuit-breakers/feed/ 11